產(chǎn)品名稱:desktop large-capacity centrifuge

產(chǎn)品型號(hào):SG-851-type

更新時(shí)間:2019-05-05

廠商性質(zhì):生產(chǎn)廠家

訪問(wèn)次數(shù):3270

產(chǎn)品報(bào)價(jià):

產(chǎn)品特點(diǎn):SG-851-type desktop large-capacity electric centrifuge is the company to meet the needs of various laboratories, carefully designed and sophisticated process technology

產(chǎn)品詳細(xì)資料:

SG-851-type desktop large-capacity electric centrifuge is the company to meet the needs of various laboratories, carefully designed and sophisticated process technology, large capacity for various types of laboratory experiments by centrifugation of precision instruments。
This high-speed centrifuges used centrifuge rotor rotating centrifugal force generated by the powerful, to speed up the settling velocity of particles in the liquid, the samples of different sedimentation coefficient and buoyant density of the material separate, is a non-uniform system of liquid separation equipment.

Features:
1, attractive appearance, small size, fully functional
2, light weight, large capacity
3, simple, easy to use
4, stable, adjustable speed and can automatically adjust the balance
5, low temperature rise of high efficiency, wide adaptability
6, applies to the hospital laboratory, biochemistry laboratory for qualitative analysis, for plasma, serum, urea, and vaccine manufacturing use.

Technical data:

1, time range 0-60
2, rated power: 200W
3, speed range :500-6000 r / min
4, centrifugal Capacity: 50ml * 6
5, the centrifugal force: 7250g
6, Dimensions (mm): length * width * height 380 * 280 *270

Handling Precautions
Work in a high speed centrifuge, used to safety and to ensure that the equipment to maintain high precision work, we must do the following:
(1).Centrifuges used to be placed in a smooth, strong on the counter; large-capacity high-speed low-speed centrifuge and refrigerated centrifuge to be placed accordingly on the ground in a solid, level place. Centrifuge work done, the load balancing, weight error as small as possible, otherwise it will cause severe vibration, and shaft damage turned centrifuge.
(2).Centrifuge starts, switch knob should be on the low speed position, start and then gradually adjust to the desired value. A work, shall knob again transferred to low-bit work, at high speed block ban on direct start.
(3).Rotor in the strict inspection before each use if a foreign body and the dirt hole, in order to maintain balance. Turned around and must be kept dry and clean, do not impact abrasion. Such as accidentally dropped, turned to X-ray film should check that no internal injury can continue to use. Turned after each use with warm water (50 ℃ ~ 60 ℃) and neutral detergent immersion cleaning, and finally with distilled or deionized water rinse, soft cloth after drying with hair dryer, wax, dry place.
(4).Pull all kinds of tube length, strength and stretch are different, should the need to use, the tube can be made of many different materials, such as polyethylene, cellulose, polycarbonates, polypropylene. Use care to ensure the sample, non-corrosive materials, solvent and gradient centrifuge tube and cap components. Expired, the aging, there are cracks or corrosion of the tube by minimizing or spin-down use. Control the use of plastic tube number, pay attention to standard matching. Centrifugal process may open the centrifuge lid, not by hand or foreign body collisions are turned and the rotation of the centrifuge tube.
(5) To ensure safety, be sure to use ground wire
(6).In the centrifuge process, such as abnormal phenomena, such as the noise and vibration is not normal, should immediay stop checks, not to find reasons not to continue to operate .
(7).Daily use of centrifuges in the process, every three months the level of response to host a degree of correction for each transfer using 500 million deal with a vacuum pump oil, working 500h should check drive motor carbon brush, preferably with a vacuum cleaner to friction toner remove, if necessary, to replace carbon brushes or commutator with fine sandpaper polish.Should be cleaned about every driver using the 1500h site with high-speed bearings and grease shaft and turned rust-proof joint of fat should be kept painted, do not be long-term anti-rust oil coating oil paper wrap. When not in use should be switched each month low 1 or 2 times, each time 0.5h, to ensure the normal operation of the site.
(8). Be sure to place the centrifuge tube placed symmetrically, and to keep the weight fairly. Things in the open centrifuge to centrifuge lid.
(9). Centrifugal liquid should not be too low boiling point,Should pay attention to internal and external pressure ratio.If it is toxic reagents, but also good ventilation treatment.
 

 相關(guān)同類產(chǎn)品:

留言框

  • 產(chǎn)品:

  • 您的單位:

  • 您的姓名:

  • 聯(lián)系電話:

  • 常用郵箱:

  • 省份:

  • 詳細(xì)地址:

  • 補(bǔ)充說(shuō)明:

  • 驗(yàn)證碼:

    請(qǐng)輸入計(jì)算結(jié)果(填寫(xiě)阿拉伯?dāng)?shù)字),如:三加四=7

上海碩光電子科技有限公司 版權(quán)所有

ICP備案號(hào):滬ICP備14032911號(hào)-5 管理登陸 技術(shù)支持:化工儀器網(wǎng)   總流量:492835  sitemap.xml

在線客服
  • 劉先生

    021-65682142

    13816422470

在線客服
用心服務(wù) 成就你我
无遮挡又黄又刺激的视频| 国产精品久久日日苍井空| 成人精品视频99在线观看免费| 淫荡少妇电影| 国产麻豆一精品一av一免费| 国产一区二区三区乱码| 免费国产又色又爽又黄的网站| 无码粉嫩虎白一线天在线观看| 久久99国产精一区二区三区| 欧美成人在线视频| 夜里十大禁用短视频软件破解版| 男与女电影| 亚洲色大成网站www| 亚洲小说春色综合另类| 国产99久久久国产精品免费看| 国产成人无码午夜视频在线观看| 中文字幕aⅴ人妻一区二区| 精品少妇人妻av免费久久洗澡| 亚洲日韩精品欧美一区二区| 少妇连续高潮抽搐| 色欲色av免费观看| 天干天干天夜夜爽啪啪免费网站| 中文av人妻av无码中文| 亚洲精品久久久久久久久久久| 国产网红无码精品视频| 欧美性欧美巨大黑白大战| 中文乱码字慕人妻熟女人妻| 自拍偷自拍亚洲精品被多人伦好爽 | 60岁老年熟妇在线无码| 亚洲成a人v欧美综合天堂麻豆 | 久久婷婷五月国产色综合| 国产喷水1区2区3区咪咪爱av| 成人综合伊人五月婷久久| 欧美激情综合五月色丁香 | 国产av国产精品白丝jk制服 | 亚洲成色www成人网站| 精品人妻一区二区三区四区在线| 日日噜噜噜夜夜爽爽狠狠| 韩国电影办公室的在线观看| 凸凹人妻人人澡人人添| 小罗莉极品一线天在线|